# Which instrument took the reading, and was it in calibration?

An auditor pulls a report off the pile. Which flaw detector took this reading, and was
it in calibration on the day?

The instrument number is on the report, typed into a box at the time. The calibration
certificate for that instrument is in a folder on the server, or still with the
calibration house. The register that ties the two together is a spreadsheet that one
person keeps, so everyone else has to ask for it. So somebody now matches a number typed
in March against a certificate filed in February, while the auditor waits.

It nearly always lines up, and proving that takes twenty minutes every time somebody
asks. Once or twice a year it does not, because a due date passed while the instrument
was on the bench and nobody on the floor had any way to know.

## What it costs

The twenty minutes is an irritation. The real cost is a reading taken on an instrument
that had gone out of calibration, found weeks later by somebody checking the paperwork,
long after it went back on the shelf.

Everything that instrument touched between the due date and the day it was found is now
in question. That is a retest, a report withdrawn and reissued, and an awkward call to
the client. The technician did nothing wrong. The due date was recorded somewhere they
never see, so nothing warned them while the instrument was in their hand.

## What good looks like

None of this needs a new process on the floor.

Keep the due date with the instrument in one register, so a reminder and a spreadsheet
cannot disagree. Show the person picking it up its state on the screen they are already
filling in. Fill the instrument's details on the report from the register, so the number
on the report is the register's number rather than one copied off a label.

None of this should block the work. Somebody on site at six in the morning cannot fix a
calibration record, and if the system stops them the job gets done on paper and the
record is lost.

## How Stratum Track does it

Your instruments live in one **Equipment Register**, in Settings. Each one carries its
description, serial number, type, manufacturer, model, range, when it was last
calibrated, when calibration is next due, and the certificate number.

![The Equipment Register, with Due soon and Out of calibration chips beside two instruments](/assets/screens/equipment-01-register.webp)

Stratum Track marks the state on the row. An instrument whose due date has passed
carries a red
**Out of calibration** chip, one due inside thirty days carries an amber **Due
soon**, and the filter row at the top shows either list on its own. An instrument with
no due date recorded is left alone, because a shop that tracks a yoke by serial number
and nothing else should not get warnings about a due date it never entered.

On the job, your technician picks the instrument from that register and Stratum Track
fills in the fields you have linked.

![A technician picking an instrument on a step, with its details filled in and a red calibration warning](/assets/screens/equipment-02-on-the-step.webp)

If the instrument they picked is overdue, Stratum Track says so under the picker, with
the date: **Calibration was due on 12/08/2026.** The technician can carry on, and the
record shows the warning was on the screen when they picked the instrument.

## Setting it up

### Step 1: Load the register

Go to **Settings**, then **Equipment Register**. Press **Add equipment** to type one in,
or **Import** to load the whole sheet at once.

The import takes an Excel file or a CSV. The first row names the columns, one column has
to hold the Equipment ID, and Stratum Track also recognises headings like Asset No and
Tag No. Write dates as dd/mm/yyyy. A column it does not recognise is left out and it
tells you which one.

Importing again is safe. An ID it already has updates that row, an ID it has not seen is
added, and nothing is ever deleted or retired by an import. So you can keep editing the
register in your spreadsheet for as long as you want.

### Step 2: Put the picker on the step

Open **Manage Templates**, open the template with **Actions**, then **Review**. Add a
field to the step your technician records the test on, and set **Field Type** to
**Equipment**, which makes it the picker your other fields follow.

### Step 3: Link the details you want filled in

Add an ordinary field for each detail you want on the record: serial number, last
calibrated, certificate number, whatever your report prints. Open its settings and press
**Link to the equipment register**, choose the **Equipment picker** it follows, choose
the **Detail to fill**, then **Save link**.

Your technician picks once and every linked field fills from that instrument. They can
still type over any of them, and Stratum Track shows what the register said.

### Step 4: Decide what happens when the instrument is not in the register yet

A technician who reaches for a gauge that nobody has entered can add it from the job
without stopping. The new row goes into the register marked **Added on a job**, and a
**Needs review** count appears at the top of the register so a manager can check it and
complete it properly. The work carries on.

## Questions people ask

#### Does Stratum Track stop a job when the instrument is out of calibration?

No. It shows the technician a plain sentence with the date, in red, as they pick the
instrument, and lets them carry on. We chose that deliberately. A technician on site
cannot recalibrate anything, and a picker that refuses them is a picker they work around
by typing the number in by hand, which loses you both the warning and the record. You
get a record that the state was on the screen when the instrument was picked.

#### Where does the thirty days come from?

Thirty days is about the booking lead time for a calibration house, so an instrument
that turns amber can still go out and come back without leaving service unexpectedly. An
instrument is treated as in calibration up to and including its due date, not the day
before.

#### Can I still keep the register in a spreadsheet?

You can keep working from your spreadsheet and import it whenever it changes. Nothing is
deleted by an import and a column your file leaves out is left as it is, so a partial
sheet updates only what it carries. You can also press **Download** to export the
register as a CSV, edit it, and import it again.

#### Does this make my records compliant?

No, and be careful of anybody who says otherwise. Your quality system decides what
evidence you keep and your accreditation is yours. Stratum Track makes the evidence a
by-product of doing the work. The instrument on the report is the one your technician
picked, and its certificate number came from your register rather than from memory. The
state it was in on the day is on the job.

#### Is the equipment register switched on for everyone?

Not yet. It is enabled per company, so tell us you want it and we will turn it on for
your workshop and load your register with you.